Yaskawa DR2 Sigma Servo User Manual

Page 248

Advertising
background image

SERVO SELECTION AND DATA SHEETS

5.3.1 Ratings and Specifications cont.

236

3) Ratings and Specifications of DR2 Servopack for Position Control

Voltage

200 VAC

100 VAC

Servopack Type

DR2- A3AC

A5AC

01AC

02AC

04AC

08AC

A3BC

A5BC

01BC

02BC

03BC

Max. Applicable Motor Capacity

W (HP)

30

(0.04)

50

(0.07)

100

(0.13)

200

(0.27)

400

(0.53)

750

(1.01)

30

(0.04)

50

(0.07)

100

(0.13)

200

(0.27)

300

(0.40)

Combined

S

ifi

Motor

Type

A3Aj A5Aj

01Aj

02Aj

04Aj

08Aj

A3Bj A5Bj 01Bj 02Bj 03Bj

Specifica-

tions

Motor Capacity

W (HP)

30

(0.04)

50

(0.07)

100

(0.13)

200

(0.27)

400

(0.53)

750

(1.01)

30

(0.04)

50

(0.07)

100

(0.13)

200

(0.27)

300

(0.40)

Rated/ Max.

Motor Speed

3000/4500 r/min

3000/4500 r/min

Applicable

encoder

Incremental encoder 2048 P/R, absolute encoder 1024 P/R

Allowable Load

Inertia*

1

J

L

kg¡m

2

¢

10

−4

(oz in s

2

¢

10

−3

)

0.63

(8.80)

0.78

(11.0)

1.20

(17.0)

3.69

(52.2)

5.73

(81.1)

20.1

(284.6)

0.63

(8.80)

0.78

(11.0)

1.20

(17.0)

3.69

(52.2)

5.73

(81.1)

(oz¡in¡s

2

¢

10

−3

)

SGM (Upper)/

SGMP (Lower)

1.95

(27.6)

6.27

(88.8)

10.41

(147.4)

18.5

(262.0)

1.95

(27.6)

6.27

(88.8)

10.41

(147.4)

Combined

Specifica-

ti

Continuous Output

Current*

7

0.42

0.6

0.87

(0.89)

2.0

2.6

4.4

(4.1)

0.63

0.90

2.2

2.7

3.7

(4.3)

p

tions

Max. Output Current

1.3

1.9

2.8

6.0

8.0

13.9

2.0

2.9

7.1

8.4

14.8

Basic

Specifica-

ti

Power Supply

(Main/control circuit)

Single-phase 200 to 230 VAC, +10% to −15%,

50/60 Hz*

2

Single-phase 100 to 115 VAC*

2

, +10% to

−15%, 50/60 Hz

p

tions

Control Method

Single-phase, full-wave rectification IGBT-PWM (sine-wave driven)

Feedback

Incremental encoder 2048 P/R, absolute encoder 1024 P/R

Loca-

i

Ambient Temp.

0 to 55°C*

3

tion

Storage Temp.

−20°C to +85°C

Ambient/Stor-

age Humidity

90% or less (with no condensation)

Vibration/Shock

Resistance

0.5/2G

Structure

Rack-mounted*

5

Approx. Mass

kg (lb)

2.5 (5.51)

3.7 (8.16)

2.5 (5.51)

3.7 (8.16)

Perfor-

Bias Setting

0 to 450 r/min. (Setting resolution: 1 r/min.)

mance

Feed Forward

Compensation

0 to 100% (Setting resolution: 1%)

Position Complete Width

Setting

0 to 250 reference units.
Reference unit: minimum unit of position data which moves load

Input

Signal

Refer-

ence

P l

Type

SIGN + PULSE train, 90° phase difference 2-phase pulse, (A-phase+B-phase), CCW pulse+CW

pulse

g

Pulse

Pulse Form

Line driver (+5 V level), open collector (+5 V or +12 V level)

Pulse

Frequency

0 to 450 kpps

Control Signal

CLEAR (input pulse form identical to reference pulse)

I/O

Signals

Posi-

tion

Output Form

A-, B-, C-phase line driver*

6

Signals

tion

Out-

put

Frequency

Dividing Ratio

(16 to N) /N (N=2048, 1024)*

4

Sequence Input

Servo ON, P drive (or motor forward/reverse by internal speed setting), forward run stop (P-OT),

reverse run stop (N-OT), alarm reset, current limit + selection (or internal speed selection), current

limit − selection (or internal speed selection)

Sequence Output

Positioning complete, motor running output (or external brake interlock), servo ready, servo alarm,

3-bit alarm codes

Dynamic Brake

Operated at main power OFF, servo alarm or overtravel.

External Regenerative Unit

Required when exceeding the allowable load inertia

5

Advertising