USING THE DIGITAL OPERATOR

4.2.3 Autotuning

188

2) Changing Motor Speed

The motor speed for operation under Digital Operator control can be changed with a fol-
lowing user constant.

Cn-10

JOGSPD

Jog Speed

Unit: r/min

Setting

Range:

0 to MAX.

Speed

Factory

Setting:

500

For Speed/

Torque

Control and

Position

Control

Set the motor speed (JOG speed) in this user

constant when motor is operated using the digital

operator.

Set the motor speed (JOG speed) in this user constant when motor is operated using the
digital operator.

For details about setting the motor speed, refer to 4.1.5 Operation in User Constant Set-
ting Mode
and Appendix D List of User Constants.

4.2.3 Autotuning

No experience required to achieve optimum settings.

The Servopack contains a built-in autotuning function to automatically measure the machine
characteristics and set the user constants.
Servo drives normally require tuning to match the machine configuration and rigidity. This
tuning requires a great deal of experience and is difficult for a person unfamiliar with the tun-
ing procedure.
However, autotuning allows even totally inexperienced people to easily complete the tuning.

Autotuning

Automatically measures the

machine characteristics and

sets the user constants.

Load Inertia

Friction

Autotuning is similar to

auto-focus for a camera.

Servopack

Servomotor