Yaskawa DR2 Sigma Servo User Manual

Page 191

Advertising
background image

USING THE DIGITAL OPERATOR

4.1.5 Operation in User Constant Setting Mode cont.

178

3) Using the Setting Mode for Memory Switches (Cn-01, Cn-02)

Turn the bits of the memory switches ON and OFF

to select the functions required.

The example below shows how to turn ON Bit 4 of memory switch Cn-01.

1) Press

DSPL

SET

to select the user constant

setting mode.

2) Select the user constant number to set.

Press the

and

keys to select the

digit.

Press the

and

keys to change the

value.

3) Press

DATA

ENTER

to display the current data for

the memory switch selected at step 2.

4) Press the

and

keys to select the

bit number to set.

5) Press the

and

keys to set the

memory switch data ON or OFF for the bit
number.

6) Repeat steps 4 and 5 as often as required.

7) Press

DATA

ENTER

to store the data.

TERMS

Turning Bits ON and OFF

Memory switches use bits, not numbers, to select
functions.
Sixteen bits are available (1 to 9 and A to E). Select
the required functions by turning the appropriate bit
ON (function ON) or OFF (function OFF).

: = OFF

= ON

4

Setting

Mode

The selected

digit flashes.

User Constant

Number

Memory

Switch Data

Bit

Number

to Set

Bit Number to Set

Bit

Number

Press either key.

or

The stored data

flashes.

Advertising