2 setting the overtravel limit function – Yaskawa DR2 Sigma Servo User Manual

Page 67

Advertising
background image

APPLICATIONS OF Σ-SERIES PRODUCTS

3.1.2 Setting the Overtravel Limit Function

54

3.1.2 Setting the Overtravel Limit Function

1) The overtravel limit function forces the moving part of the machine to stop when it ex-

ceeds the movable range.

2) To use the overtravel limit function, connect the following input signal terminals correctly.

Input P-OT 1CN-42

Forward Rotation Prohibited

(Forward Overtravel)

For Speed/Torque

Control and

Position Control

Input N-OT 1CN-43

Reverse Rotation Prohibited

(Reverse Overtravel)

For Speed/Torque

Control and

Position Control

Inputs terminals for overtravel limit switch.

For linear motion, connect a limit switch to prevent
damage to the machine.

P-OT

ON: 1CN-42 is

at low level.

Forward rotation allowed. Normal operation status.

OFF: 1CN-42

is at high level.

Forward rotation prohibited (reverse rotation allowed).

N-OT

ON: 1CN-43 is

at low level.

Reverse rotation allowed. Normal operation status.

OFF: 1CN-43

is at high level.

Reverse rotation prohibited (forward rotation allowed).

3

Reverse

rotation side

Forward

rotation side

Servopack

Limit switch

Servomotor

(1CN−42)

(1CN−43)

Advertising
This manual is related to the following products: