Electrical Specifications of the Holding Brake
a) SGMP Type (Rated Voltage: 90 VDC)
Standard
. . . . . . . .
Motor Model
Motor
Capacity
(W)
Holding Brake Specifications
Capacity
(W)
Holding
Torque
(kg-cm)
Coil
Resistance
(Ω at 20°C)
Rated
Current
(A at 20°C)
SGMP-01jjjj
100
6
5.0
1555
0.062
SGMP-02jjjj
200
5
10
1573
0.056
SGMP-04jjjj
400
7.6
20
1062
0.085
SGMP-08jjjj
750
7.5
37
1083
0.083
SGMP-15jjjj
1500
10
73
832
0.11
b) SGMP Type (Rated Voltage: 24 VDC)
Semi-standard
. . . . . . . .
Motor Model
Motor
Capacity
(W)
Holding Brake Specifications
Capacity
(W)
Holding
Torque
(kg-cm)
Coil
Resistance
(Ω at 20°C)
Rated
Current
(A at 20°C)
SGMP-01jjjj
100
6
5.0
114
0.23
SGMP-02jjjj
200
5
10
116
0.21
SGMP-04jjjj
400
7.6
20
89
0.29
SGMP-08jjjj
750
7.5
37
77
0.31
SGMP-15jjjj
1500
10
73
58
0.42