SERVO SELECTION AND DATA SHEETS

5.2.1 Ratings and Specifications cont.

228

Electrical Specifications of the Holding Brake

a) SGMP Type (Rated Voltage: 90 VDC)

Standard

. . . . . . . .

Motor Model

Motor

Capacity

(W)

Holding Brake Specifications

Capacity

(W)

Holding

Torque

(kg-cm)

Coil

Resistance

(at 20°C)

Rated

Current

(A at 20°C)

SGMP-01jjjj

100

6

5.0

1555

0.062

SGMP-02jjjj

200

5

10

1573

0.056

SGMP-04jjjj

400

7.6

20

1062

0.085

SGMP-08jjjj

750

7.5

37

1083

0.083

SGMP-15jjjj

1500

10

73

832

0.11

b) SGMP Type (Rated Voltage: 24 VDC)

Semi-standard

. . . . . . . .

Motor Model

Motor

Capacity

(W)

Holding Brake Specifications

Capacity

(W)

Holding

Torque

(kg-cm)

Coil

Resistance

(at 20°C)

Rated

Current

(A at 20°C)

SGMP-01jjjj

100

6

5.0

114

0.23

SGMP-02jjjj

200

5

10

116

0.21

SGMP-04jjjj

400

7.6

20

89

0.29

SGMP-08jjjj

750

7.5

37

77

0.31

SGMP-15jjjj

1500

10

73

58

0.42