4.2 Using the Functions

187

2) Select the user constant number Cn-00.

(User constant Cn-00 is selected when the
power is turned ON.)

Press the

and

keys to select the

digit.

Press the

and

keys to change the value.

3) Press

DATA

ENTER

to display the current data for

the user constant Cn-00.

4) Press the

and

keys to change the

data to 00.
(This user constant is set to 00 when the
power is turned ON.)

5) Press

DSPL

SET

to set the Digital Operator in

operation mode. Operation is now pos-
sible under Digital Operator control.

6) Press

JOG

SVON

to set the servo ON status

(motor power turned ON).
Select Servo ON/Servo OFF

7) Press the

and

keys to operate the

motor.
Motor Forward/Reverse Rotation

8) Press

DSPL

SET

to revert to

. This

sets the servo OFF status (motor power
turned OFF).

(Alternatively, press

JOG

SVON

to set the servo

OFF status.)

9) Press

DATA

ENTER

to return to the setting mode

display. This disables operation under Dig-
ital Operator control.

4

Select Cn-00.

The selected digit

blinks.

User Constant Number

Data

Set to 00-00.

keys to change the

value.

Press the

Display for operation mode from

Digital Operator

to change.

Servo ON

- motor ON

Servo OFF

- base block

Press

Motor runs

forward while

this key is

pressed.

Motor runs

backward while

this key is

pressed.

Motor

Forward

Rotation

Motor

Reverse

Rotation