SERVO SELECTION AND DATA SHEETS

5.6.1 Cable Specifications and Peripheral Devices cont.

352

2) Cable Specifications

Cable Specifications for Main Circuit Power Input Terminals

Applied

Voltage

Servopack

Type

DR2

Main Circuit Power Input Terminal*

1

L1. L2,

DR2−

Rated Input Current

A (rms)

Cable Spec.*

2

Tightening

Torque

(N¡m)

200VAC

Class

A3A j

1.3

AWG16 (HIV 1.25) Min.

0.5

Class

A5A j

1.5

01A j

2.5

02A j

4.0

04A j

6.0

AWG14 (HIV 2.0) Min.

08A j

11.0

100VAC

Class

A3B j

2.0

AWG16 (HIV 1.25) Min.

Class

A5B j

2.6

01B j

4.5

02B j

8.0

AWG14 (HIV 2.0) Min.

03B j

14.0

*1 When P, N (Y3, Y4) terminals are used, use the same size cable as those of L1, L2.

Tightening torque is the same as those of L1, L2 (0.5N¡m).

*2 The cable specifications were selected under conditions of three cables per bundle

at 40_C ambient temperature, with the rated current flowing. Max. connectable

cable size is 2.5mm

2

.

Cable Specifications for Control Circuit Power Input Terminals

Applied

Voltage

Servopack Type

DR2−

Control Circuit Power Input Terminal

L, N

Rated Input

Current*

2

A (rms)

Cable Spec.*

1

Tightening

Torque

(N¡m)

200VAC

Class

All Models

0.2

AWG16

(HIV 1.25) Min.

0.5

100VAC

Class

All Models

0.4

*1 Max. connectable cable size is 2.5mm

2

.

*2 When control circuit breaker and main circuit breaker are used separately,

be aware of in−rush current (30 to 40 A, for 5 ms or less) flows at control power ON.