5.6 Specifications and Dimensional Drawings of Peripheral Devices

351

S

For 100VAC Class

Servopack Type

DR2-

Applicable

Servomotor

Power supply

capacity per

Servopack

*1

MCCB or

fuse

capacity

*2

Noise filter

type

(reference

Recommended noise

filter

*3

Power

ON/OFF

switch

Servopack

*1

kVA

capacity

*2

A

(reference

diagram)

Type

Spec.

switch

30 W

(0 04HP)

A3BC

SGM−A3B j

0.25

5

Applicable

LF- 205A Single-phase

200 VAC

Contactor

35A

(0.04HP)

SGM−A3W j

pp

g p

200 VAC

Class, 5 A

35A or

above

50 W

(0 07HP)

A5BC

SGM−A5B j

0.3

Class, 5 A

above

(0.07HP)

SGM−A5W j

100 W

(0.13HP)

01BC

SGM−01B j
SGM−01W j

0.5

Not

applicable

01BCP

SGMP−01B j
SGMP−01W j

applicable

200 W

(0.27HP)

02BC

SGM−02B j
SGM−02W j

0.75

8

LF- 210

Single-phase

200 VAC

Class 10 A

02BCP

SGMP−02B j
SGMP−02W j

Class, 10 A

300 W

(0.40HP)

03BC

SGM−03B j
SGM−03W j

1.4

15

LF- 220

Single-phase

200 VAC

Class 20 A

03BCP

SGMP−03B j
SGMP−03W j

Class, 20 A

Note

For power ON/OFF switch, use contactor 30A or above.

*1 Value at rated load.

*2 Braking characteristics (at 25_C): 200% for 2s min., 700% for 0.01s min.

*3 Yaskawa recommends noise filters manufactured by Tokin Corp.

Yaskawa Controls Co., Ltd. can supply these noise filters.

The types of cable are shown in the table below. Use it in combination with the table
above.

Cable Type

Conductor Allowable Temperature

C

Symbol

Name

p

_

C

PVC

Normal vinyl cable

---

IV

600 V vinyl cable

60

HIV

Temperature-resistant vinyl cable

75

Note

1) Use cable with 600 V min. withstand voltage for main circuits.

2) Consider allowable current reduction ratio if cables are bundled in PVC or metal ducts.

3) Use temperature-resistant cable under high ambient or panel temperature where nor-

mal vinyl cables rapidly deteriorate.