SERVO SELECTION AND DATA SHEETS

5.6.12 Regenerative cont.

378

2) JUSP−RG08C type

JUSP−RG08C type is an exterior type regenerative unit. When regenerative ability of the
built−in resistor is insufficient, install this regenerative unit to enhance the regenerative
ability. When regenerative resistor is installed externally, disconnect the jumper cable
between terminals Y4 and Y5. Connect exterior type regenerative unit between termi-
nals P/Y3 and Y4.

• Dimensional Drawings

M4 External Terminal Screws

Approx. Mass: 1 kg (2.20 lb)

Hole 6 dia.
(Φ0.24)

(1.97)

(0.98)

(0.73)

(5.12)

(6.30)

(5.12)

(5.87)

(0.20)

(0.59)

(0.24)

(0.24)

(0.98)

(0.59)

Nameplate

• Regenerative Unit Specifications

Type

JUSP−RG08C

Remarks

Applicable Servopack

Only for 200 V, 30 to 200 W

specifications

Regenerative Working

Voltage

380Vdc

Regenerative Processing

Current

8Adc

Regenerative Resistance:

50 Ω, 60 W

Error Detection Function

Regenerative resistance

disconnection, regenerative

transistor fault, overvoltage

Minimum Exterior Resistance 50 Ω
Alarm Output

Normally closed contact

(open when protective

function operates)

200 V operation OK

Dimensions

in mm

(inches)

55W¢160H¢130D
(2.17W ¢ 6.30H¢ 5.31D)