3.1 Setting User Constants According to Machine Characteristics

59

Preset Value: Cn-08 (TLMTF)

Cn-09 (TLMTR)
Cn-18 (CLMIF) : P-CL input only
Cn-19 (CLMIR) : N-CL input only

Note This function is changed to another function depending on the setting of bit 4 of

memory switch Cn-01.

To use output signals CLT+, CLT- as a torque limit output signal, set the following memory
switch to 0.

This memory switch can also be used to set level 2 torque restriction (described in the
next subsection).

Cn-01 Bit 4

CLT+, CLT-

Output Signals

Selection

Factory

Setting: 0

For Speed/Torque Control

Sets the output conditions for output signals CLT+ (1CN-25) and CLT- (1CN-26).

Setting

Meaning

0

Uses CLT+, CLT- output signals as a torque

limit output signal.
Compares the DR2 Servopack internal torque

(current) reference with the preset value.
Preset Value:Cn-08 (TLMTF)

Cn-09 (TLMTR)

Cn-18 (CLMIF): P-CL input only

Cn-19 (CLMIR): N-CL input only

0

Internal torque

(current) reference

preset value

Opens the circuit

between 1CN-25 and

1CN-26

Internal torque

(current) reference <

preset value

Closes the circuit

between 1CN-25 and

1CN-26

1

Uses CLT+, CLT- output signals as a speed

coincide output signal.

For details, refer to 3.7.4.

3

Bit 4 of memory switch Cn-01

Torque

limit

detection

Speed

coincide

When CLT+, CLT- output

signals are changed, the

following bit data are also

changed:
• Status indication mode bit

data

• Monitor mode Un-05 bit 4

CLT+

CLT-
(1CN-25)

(1CN-26)