Yaskawa DR2 Sigma Servo User Manual

Page 144

Advertising
background image

3.7 Forming a Protective Sequence

131

Alarm

Alarm Code Output

Servo

Alarm

Alarm Type

Alarm Description

Alarm

Display

ALO1 ALO2 ALO3

Alarm

(ALM+)

Output

Alarm Type

Alarm Description

U d fi d

Digital

Operator

transmis-

Communication error oc-

curred between Digital Oper-

ator and Servopack.

Undefined

transmis-

sion error

ator and Servopack.

¢

¢

¢

No error

○ : Output transistor is ON
¢

: Output transistor is OFF

* : Displays an alarm category number.
For details, refer to Appendix E List of Alarm Displays.

5) When the servo alarm (ALM+) is output, eliminate the cause of the alarm and set the fol-

lowing ALMRST input signal at low level (0V) to reset the alarm state.

Input ALMRST 1CN-44

Alarm Reset

For Speed/Torque

Control and

Position Control

This signal is used to reset the servo alarm state.

Alarm state can be reset using the Digital Operator.
Also, alarm state is reset at control power ON/OFF.

When an alarm occurs, always eliminate the cause before resetting the alarm
state. 6.2.1 Troubleshooting Problems with Alarm Display
describes how to trou-
bleshoot the system when an alarm arises.

3

Advertising
This manual is related to the following products: