BASIC USES OF S-SERIES PRODUCTS

26

Standard connection method for S-Series AC Servo Drives:

Molded-case circuit breaker (MCCB)

Used to protect power

supply line. Shuts the

circuit off when

overcurrent is detected.

Noise filter

Used to eliminate

external noise from

power supply line.

Types: LF-205A

(for DR2-A3A, A5A, 01A,

02A, A3B, A5B, and 01B)

LF-210

(for DR2-04A and 02B)

LF-220

(for DR2-03B and 08A)

Magnetic contactor

Turns the main power ON

or OFF.

Use a surge suppressor

for the magnetic contactor.
Type: HI-15E5 (30 A)

Brake power supply
Used for Servomotor with brake.

Types:

LPSE-2H01

(for 200 V input)

LPDE-1H01

(for 100 V input)

Regenerative unit
(For

types

DR2-A3A,

A5A, 01A, 02A)

Type: JUSP-RG08

(Not applicable to types

DR2 A3B, A5B, 01B)

Digital Operator

Allows the user

to set user

constants or

operation

references

and

display operation

status

or

alarm

status.

Power supply:

Single-phase

200 or 100 V

Connector kits for pulse generator (PG) and for

motor are not required if the following parts are

ordered:
S

Cable with terminal connectors

S

Cable with connector and amplifier terminal

L

This wiring is required

only for a Servomotor

with brake

Brake

control

relay

Connector for PG

(on Servopack side)

S-Series

DR2 Servopack

Exterior type regenerative

resistor

Applicable

to

DR2-04ACY8,

08ACY8, 02BCY8, 03BCY8)

Hand-held type

(JUSP-OP02A-1)

1-meter(3.3ft.) cable included

L2

L1

N

+(Y3), -(Y4)

U
V
W

Note: The following

noise filters do not conform to the EMC

instructions. As for the noise filters

conforming to EMC instructions, refer

to 7.2.2.

See

the

precautions

on

wiring

(on

the

previous page).

U

V

W

Connector for PG

(on Servopack side)

This wiring is required

only for a Servomotor

with brake

Advertising