SERVO SELECTION AND DATA SHEETS

5.2.1 Ratings and Specifications cont.

222

*

2

Rated torques are continuous allowable torque values at 40°C with an attached heat sink

as specified below.

Heat sink dimensions 01A, 02A, 04A

250¢250¢6(mm), (9.84¢9.84¢0.24 (in.))

.

08A

300¢300¢12(mm),(11.81¢11.81¢0.47(in.))

. . . . . . . . . .

Electrical Specifications of the Holding Brake

a) SGMP Type (Rated Voltage: 90 VDC)

Standard

. . . . . . . .

Motor Model

Motor

Capacity

(W)

Holding Brake Specifications

Capacity

(W)

Holding

Torque

(kg-cm)

Coil

Resistance

(at 20°C)

Rated

Current

(A at 20°C)

SGMP-01jjjj

100

6

5.0

1555

0.062

SGMP-02jjjj

200

5

10

1573

0.056

SGMP-04jjjj

400

7.6

20

1062

0.085

SGMP-08jjjj

750

7.5

37

1083

0.083

b) SGMP Type (Rated Voltage: 24 VDC)

Semi-standard

. . . . . . . .

Motor Model

Motor

Capacity

(W)

Holding Brake Specifications

Capacity

(W)

Holding

Torque

(kg-cm)

Coil

Resistance

(at 20°C)

Rated

Current

(A at 20°C)

SGMP-01jjjj

100

6

5.0

114

0.23

SGMP-02jjjj

200

5

10

116

0.21

SGMP-04jjjj

400

7.6

20

89

0.29

SGMP-08jjjj

750

7.5

37

77

0.31