• When detector EXE650B (interpolation magnification: 25) is used:

8MHz Clock

10MHz Clock

Switching

Max. Input

Frequency

fE max

Min. Edge

Interval

a min

Min. Pulse

Width

b min

Max. Input

Frequency

fE max

Min. Edge

Interval

a min

Min. Pulse

Width

b min

S3

S4

Approx.

60kHz

0.125µs

0.125µs

Approx.

60kHz

0.1µs

0.1µs

×

×

40kHz

0.25µs

0.25µs

50kHz

0.2µs

0.2µs

×

20kHz

0.5µs

0.5µs

25kHz

0.4µs

0.4µs

×

10kHz

1.0µs

1.0µs

12.5kHz

0.8µs

0.8s

(×: Switch is closed)

2) Application Review

a) Linear Scale :

Input Frequency =

Operation Speed

Scale Interval =

1200∕60

0.01

= 2000PPS < EXE650B Max.InputFrequency

b) Min. Edge Interval and Pulse Width

DR2 receivable max. frequency : 675kHz

10

6

675000 × 4 =

0.3704 μs < Min. Edge Interval

• With the above a) and b), switching S

3

and S

4

at 8MHz clock can be performed under

both of the following conditions:

Max. Input

Frequency

S

3

S

4

20kHz

×

10kHz

c) Feedback Frequency to Detector Output Frequency and Error Counter

Detector Output Frequency = 2000 ×25 = 50000PPS ! 50kPPS

Feedback Frequency = 50 ×4 = 200kPPS

d) DR2 User Constant (Cn-24, -25)

* Electronic Gear = BA =

Cn–24

Cn–25 =

Cn–2A × 4

4×6

0.0001×10

=

6000 × 4

24000 =

1

1

G