3 using positioning complete signal, Output → coin+ 1cn-25, Output → coin- 1cn-26 – Yaskawa DR2 Sigma Servo User Manual

Page 146

Advertising
background image

3.7 Forming a Protective Sequence

133

3.7.3 Using Positioning Complete Signal

1) This section describes how to wire and use contact output-signal “positioning complete

output (COIN).” This signal is output to indicate that servomotor operation is complete.

Photocoupler output

Per output:

Maximum operation voltage:

30 VDC

Maximum output current:

50 mADC

Servopack

I/O power

supply

1CN-25

1CN-26

COIN+

COIN-

Output COIN+ 1CN-25

Positioning Complete Output

For Position

Output COIN- 1CN-26

For Position

Control Only

For position control only.

This output signal indicates that motor operation
is complete during position control. The host con-
troller uses this signal as an interlock to confirm
that positioning is complete.

ON
status:

Circuit between 1CN-25 and 1CN-26 is
closed.
1CN-25 is at low level.

Positioning is complete (position error is
below the preset value).

OFF
status:

Circuit between 1CN-25 and 1CN-26 is
open.
1CN-25 is at high level.

Positioning is not complete (position
error is over the preset value.)

Preset Value: Cn-1B (positioning complete range)

2) Set the number of error pulses in the following user constant Cn-1B to adjust output tim-

ing of COIN (positioning complete output).

3

Positions

Speed

Reference

Motor

Error

pulse

COIN+

(1CN-25)