3.2 Setting User Constants According to Host Controller

75

Cn-02 Bit A

Error Counter Clear Signal

Selection

Factory

Setting: 0

For Position Control Only

Selects the pulse form of error counter clear signal CLR (1CN-15).

Setting

Meaning

0

Clears the error counter when the CLR

signal is set at high level. Error pulses

do not accumulate while the signal

remains at high level.

Cleared state

(1CN-15)

1

Clears the error counter only once when

the rising edge of the CLR signal rises.

Cleared only once at this point

(1CN-15)

Cn-01 Bit A

Error Counter Processing at

Servo OFF

Factory

Setting: 0

For Position Control Only

Select the error counter processing at Servo OFF.

Setting

Meaning

0

Error counter is cleared at Servo OFF.

1

Error counter is not cleared at servo OFF.

3