Yaskawa DR2 Sigma Servo User Manual

Page 394

Advertising
background image

SERVO SELECTION AND DATA SHEETS

5.6.15 Cables for Connecting PC and Servopack cont.

382

• Shift Control:

None

• Communications Method:

Semi-duplex

Servopack End (3CN)

RS-232C Port (Personal Computer End)

Shield

Case

Note: Maximum cable length is 2 m (6.56 ft).

3) Connection is also possible to the RS-422A port. In this case, the connection circuit is as

follows:

• Transmission Distance: 30 m (98.4 ft) max.

• Transmission System: RS-422A

Servopack End (3CN)

RS-422A Port (Personal Computer End)

Shield

Case

• Terminal Arrangement at Servopack End

Pin

#

Signal Name

Signal Circuit Name

Signal Direction

1

TXD

Transmit data (not inverted)

P←S

2

*TXD

Transmit data (inverted)

P←S

3

RXD

Receive data (not inverted)

P→S

4

*RXD

Receive data (inverted)

P→S

5

OPH

#

6

*RXD

Shorting pins 6 and 7 inserts 220 Ω termination resistance

7

RT

g p

between RXD and *RXD.

8

5VPP

#

9

GND

Signal ground 0 V

P: Personal computer
S: Servopack
#: Terminal not used, leave open.