A.c1 – Yaskawa DR2 Sigma Servo User Manual

Page 415

Advertising
background image

6.2 Troubleshooting

403

Status When Alarm Occurred

A

,

B

During servomotor

operation

At control power ON

C

Cause

Remedy

A

Part malfunctioned in reference read-in unit

(A/D converter, etc.).

Reset alarm and restart operation.

B

Part defective in reference read-in unit

(A/D converter, etc.).

Replace Servopack.

C

Circuit board (1PWB) defective

Replace Servopack.

D

Display and Outputs

Digital Operator

Di l

d

Alarm Output

g

p

Display and

Alarm Name

Alarm Code Output

Alarm Output

Alarm Name

ALO1

ALO2

ALO3

p

A.C1

Servo overrun

ON

OFF

ON

OFF

OFF: Output transistor is OFF
ON: Output transistor is ON

Status When Alarm Occurred

E

At control power ON

User constant

Cn-01 Bit 0 = 0

When servo ON (S-ON)

signal turned ON

A

,

B

, C, D, E

On speed reference input

A

,

B

, C, D, E

A

,

B

, C, D, E

Occurred 1 to 3 se-

conds after power ON

User constant

Cn-01 Bit 0 = 1

Cause

Remedy

A

Servomotor wiring incorrect or

disconnected

Check wiring and connectors at

servomotor.

B

Encoder wiring incorrect or disconnected

Check wiring and connectors at encoder.

C

Incremental encoder power not supplied

from Servopack.

Use the Servopack power supply for the

encoder.

D

Encoder defective

Replace servomotor.

E

Circuit board (1PWB) defective

Replace Servopack.