Yaskawa DR2 Sigma Servo User Manual

Page 166

Advertising
background image

3.8 Special Wiring

153

Use the following user constant to set the number of pulses for the absolute en-
coder to be used:

Cn-11

PULSNO

Number of Encoder

Pulses

Unit:

P/R

Setting

Range:

Number of

Encoder

Pulses

Factory

Setting:

2048

For Speed/Torque

Control and Position

Control

Sets the number of encoder pulses according to the servomotor type to be used.
After changing this user constant setting, turn the power OFF, then ON. This makes the
new setting valid.

Motor Type

Number of Encoder Pulses Per Revolution

Preset
Value

SGM-jjj31j
SGMP-jjj31j

Incremental encoder: 2048 pulses per revolution

2048

SGM-jjjW1j
SGMP-jjjW1j

Absolute encoder

:

1024 pulses per revolution

1024

5) Using a Battery

Use the following battery to enable the absolute encoder to store position information
even when the power is turned OFF. Load the battery in the host controller and connect it
to Servopack input terminals BAT and BAT0.

Recommended battery:

D

Connect the battery securely to prevent contact faults

Recommended battery:

Connect the battery securely to prevent contact faults
resulting from environmental changes or aging.

Lithium battery
Toshiba Battery ER6V C3 Type

3.6 V, 2000 mAH

D

Battery voltage is not monitored inside the Servopack.
Provide a battery voltage monitor circuit as necessary.

Minimum voltage: 2.8 V

6) Setting up Absolute Encoder

a) Set up the absolute encoder in the following cases:

• When starting the machine for the first time

• When the absolute encoder is not connected to power supply or backup power supply

(battery) for more than two days

NOTE

Improper setup may cause malfunctions such as improper encoder operation and/or
strain on the battery. Follow the setup procedure on the next page.