Alarm display – Yaskawa DR2 Sigma Servo User Manual

Page 487

Advertising
background image

LIST OF ALARM DISPLAYS

478

Alarm Display

Alarm Display

Di i l

7-

Alarm Output

Alarm Name

Meaning

Remarks

p y

on Digital

Operator

segment

LED

Alarm Code Output

ALM

O

g

Operator

LED

ALO1

AL02

AL03

Output

OFF

OFF

OFF

OFF

Absolute data

error

Absolute data fails to be

received, or received

absolute data is

abnormal.

For

absolute

encoder

only

OFF

OFF

OFF

OFF

User constant

breakdown

Checksum results of

user constants are

abnormal.

OFF

OFF

OFF

OFF

User constant

setting error

The user constant

setting is outside the

allowable setting range.

ON

OFF

OFF

OFF

Overcurrent

An overcurrent flowed

through the power

transistor.

OFF

ON

OFF

OFF

Blown fuse

Fuse is blown.

ON

ON

OFF

OFF

Regenerative

error

Defective regenerative

resistor

Regenerative resistor

disconnection

ON

ON

OFF

OFF

Position error

pulse overflow

Position error pulse has

exceeded the value set

in user constant Cn-1E

(overflow).

For

position

control

only

OFF

OFF

ON

OFF

Overvoltage or

undervoltage

The main circuit voltage

for motor operation has

become too high or too

low.

ON

OFF

ON

OFF

Overspeed

Motor speed has

exceeded 4950 r/min.

ON

ON

ON

OFF

Overload

Rated torque was

exceeded during

continuous operation.

OFF

OFF

OFF

OFF

Absolute

encoder error

The number of pulses

per absolute encoder

revolution is abnormal.

For

absolute

encoder

only

OFF:

Output transistor is OFF

ON

:

Output transistor is ON

TERMS

Checksum

An automatic check function for a set of data such as user constants. It stores the sum of
user constant data, recalculates the sum at specific timing, and then checks whether the
stored value matches the recalculated value. This function is a simple method of checking
whether a set of data is correct.