A.c4, A.c7 – Yaskawa DR2 Sigma Servo User Manual

Page 418

Advertising
background image

INSPECTION, MAINTENANCE, AND TROUBLESHOOTING

6.2.1 Troubleshooting Problems with Alarm Display cont.

406

D

Display and Outputs

Digital Operator

Di l

d

Alarm Output

g

p

Display and

Alarm Name

Alarm Code Output

Alarm Output

Alarm Name

ALO1

ALO2

ALO3

p

A.C4

Encoder C-phase

disconnection

A.C7

External PG

C-phase

disconnection

(only for

full-closed loop

specification)

ON

OFF

ON

OFF

OFF: Output transistor is OFF
ON: Output transistor is ON

Status When Alarm Occurred

C

At main circuit power

ON

User constant

Cn-01 Bit 0 = 0

When servo ON (S-ON)

signal turned ON

A

, B, C, D

During servomotor

operation

A, B, C, D

A

, B, C, D

Occurred 1 to 3 seconds

after main circuit power

ON

User constant

Cn-01 Bit 0 = 1

Cause

Remedy

A

Encoder wiring incorrect or poor

connection

Check wiring and connectors at encoder.

B

Noise in encoder wiring.

Separate encoder wiring from main wiring

circuits.

C

Encoder defective

Replace servomotor.

D

Circuit board (1PWB) defective

Replace Servopack.

6

Advertising
This manual is related to the following products: