background image

LIST OF USER CONSTANTS

472

Category

Remarks

Factory

Setting

Upper

Limit

Lower

Limit

Unit

Name

Code

User

Constant

No.

Sequence

Related

Constants

Cn-16

BRKWAI

Output timing

of brake

reference

during motor

operation

10 ms

10

100

50

See 3.4.4.

Cn-1B

COINLV

Positioning

complete range

Reference

unit

0

250

7

See 3.7.3.

Pulse

Related

Constants

Cn-0A

PGRAT

Dividing ratio

setting

P/R

16

32768

2048

See note 1

See 3.2.3.

Cn-11

PULSNO

Number of

encoder pulses

P/R

513

32768

2048

See note 1

See 3.3.3,

3.8.5.

Cn-24

RATB

Electronic gear

ratio

(numerator)

4

65535

4

See note 3

See 3.2.3,

3.2.5.

Cn-25

RATA

Electronic gear

ratio

(denominator)

1

65535

1

See note 3

See 3.2.3,

3.2.5.

Cn-2A

PULSNO2

External PG

number of

pulses

P/R

513

32768

2048

Other

Constants

Cn-0C

TRQMSW

Mode switch

(torque

reference)

%

0

Max.

torque

200

See 3.6.6.

Cn-0D

REFMSW

Mode switch

(speed

reference)

r/min

0

4500

0

See 3.6.6.

Cn-0E

ACCMSW

Mode switch

(acceleration

reference)

10 (r/min)/s 0

3000

0

See 3.6.6.

Cn-0F

ERPMSW

Mode switch

(error pulse)

Reference

unit

0

10000

0

See 3.6.6.

Cn-10

JOGSPD

Jog speed

r/min

0

4500

500

See 3.3.2.

Cn-1E

OVERLV

Overflow

×256

reference

unit

1

32767

1024

See note 4

See 3.5.2,

3.6.2.

Cn-1F

SPEED1

1st speed

(contact input

speed control)

r/min

0

4500

100

See 3.2.6.

Cn-20

SPEED2

2nd speed

(contact input

speed control)

r/min

0

4500

200

See 3.2.6.

Cn-21

SPEED3

3rd speed

(contact input

speed control)

r/min

0

4500

300

See 3.2.6.

Cn-28

NFBCC

Speed loop

compensation

constant

---

0

100

0

: User constants that must be always set