5.3 Servopack Ratings and Specifications

237

Overtravel

Dynamic brake stop at P-OT or N-OT or deceleration stop

Protective Functions

Overcurrent, overload, overvoltage, overspeed, overrun prevention, origin error, CPU error,

encoder error, overflow, fuse blown, undervoltage

Indicators

Power (green LED) and status/alarm (red, 7-segment LEDs)
Digital operator: status/alarm (red, 7-segment LEDs ×5)

Others

Brake interlock signal output, reverse run connection, JOG run, electronic gear, auto-tuning

*

1

Allowable load inertia ranges require no optional external regenerative unit (applica-
ble to 200V 30W to 200W) or external regenerative resistor (applicable to 100V 200W,
300W or 200V 400W, 750W). Values are when motor speed is 3000r/min max. If load
inertias exceed these ranges, restrict the operation or use a regenerative unit (appli-
cable to 200V 30W to 200W) or external regenerative resistor (applicable to 100V
200W, 300W or 200V 400W, 750W).
For details, refer to 5.3.5 Load Inertia.

*

2

Supply voltage should not exceed 230 V + 10% (253 V) or 115 V + 10% (127 V). A
step-down transformer is required if the voltage should exceed these values.

*

3

Use within the ambient temperature range. When enclosed in a box, the internal tem-
peratures must not exceed the ambient temperature range.

*

4

N is the number of encoder pulses.

*

5

Base mount can be available as an option (DR2-jjY7).

*

6

Open collector output can be available as an option (DR2-jjY1).

*

7

Values in parenthesis show SGMP type Servomotor.

5