Yaskawa DR2 Sigma Servo User Manual

Page 218

Advertising
background image

SERVO SELECTION AND DATA SHEETS

5.1.1 Selecting a Servomotor cont.

206

SGM- 01 3 1 2 j

SGM type

SGMP type

Σ-Series

SGM: SGM Servomotor

SGMP: SGMP Servomotor

(cube type)

1) Rated output (motor capacity)

(Type SGM only)
A3: 30W (0.04HP)

A5: 50W (0.07HP)

(Types SGM and SGMP)
01: 100W (0.13HP) 02: 200W (0.27HP)
03: 300W (0.40HP) 04: 400W (0.53HP)
08: 750W (1.01HP)

2) Supply voltage

A: 200V B: 100V
V: 200V W: 100V
(V and W are EN Standard application)

U: 200V L: 100V
(U and L are UL Standard application)

3) Encoder specification

3: 2048 P/R incremental encoder
W: 12-bit absolute encoder (Available upon special request)
S: 15-bit absolute encoder
4: 2000 P/R incremental encoder

4) Design revision order
5) Shaft specification

2: Straight without key
4: Straight with key

6) Options

B: with brake

S: with shaft seal

D: with brake and shaft seal
P: drip-proofed

Flowchart for Servomotor selection

Selected motor type

D

D

D

D

D

D

Example

Axis 1

Axis 2

D

D

D

Axis 3

Axis 4

Axis 5

A

V

SGM-jjjjjjj
SGM-jjjjjjj
SGM-jjjjjjj

SGM-jjjjjjj

SGM-jjjjjjj

5