Yaskawa DR2 Sigma Servo User Manual

Page 157

Advertising
background image

APPLICATIONS OF Σ-SERIES PRODUCTS

3.8.2 Wiring for Noise Control cont.

144

Ground the 0 V line (such as SG-V and SG-T) of the reference input line. If the main circuit
wiring for the motor is accommodated in a metal conduit, ground the conduit and its junc-
tion box. For all grounding, always use one-line grounding.

3) Noise Filter Installation

a) Use an inhibit type noise filter to prevent noise

from the power supply line.

Install a noise filter on the power supply line for
peripheral equipment as necessary.

The following table lists recommended noise
filters for each Servopack type.

Noise Filter Types

Power

Servopack Type

Noise Filter

Recommended Noise Filter

Power

Voltage

Servopack Type

Noise Filter

Connection

Type

Specifications

30 W

(0.04 HP)

DR2-A3Aj

LF-205A

Single-phase

200 VAC, 5 A

50 W

(0.07 HP)

DR2-A5Aj

00

C, 5

200 V

100 W

(0.13 HP)

DR2-01Aj

200 V

200 W

(0.27 HP)

DR2-02Aj

(Correct)

400 W

(0.53 HP)

DR2-04Aj

LF-210

Single-phase

200 VAC, 10 A

750 W

(1.01 HP)

DR2-08Aj

LF-220

Single-phase

200 VAC, 20 A

30 W

(0.04 HP)

DR2-A3Bj

(Incorrect)

LF-205A

Single-phase

200 VAC, 5 A

50 W

(0.07 HP)

DR2-A5Bj

00

C, 5

100 V

100 W

(0.13 HP)

DR2-01Bj

200 W

(0.27 HP)

DR2-02Bj

LF-210

Single-phase

200 VAC, 10 A

300 W

(0.39 HP)

DR2-03Bj

LF-220

Single-phase

200 VAC, 20 A

Note These noise filters are manufactured by Tokin Corp. and available from Yaskawa.

For noise filters, contact your nearest Yaskawa sales representatives.