Snmp trap link-status – ADTRAN 1000R Series User Manual

Page 1213

Advertising
background image

Command Reference Guide

VLAN Interface Config Command Set

61200510L1-35E

Copyright © 2005 ADTRAN

1213

snmp trap link-status

Use the snmp trap link-status command to control the Simple Network Management Protocol (SNMP)
variable ifLinkUpDownTrapEnable (RFC 2863) to enable (or disable) the interface to send SNMP traps
when there is an interface status change. Use the no form of this command to disable this trap.

Syntax Description

No subcommands.

Default Values

By default, the ifLinkUpDownTrapEnable OID is set to enabled for all interfaces except virtual Frame Relay
interfaces.

Applicable Platforms

This command applies to the NetVanta 300, 1000, 1000R, and 2000 Series units.

Command History

Release 1.1

Command was introduced.

Release 3.1

Command was extended to the SHDSL interface.

Release 5.1

Command was expanded to include Gigabit Ethernet, port channel, VLAN, E1,
and G.703 interfaces.

Release 6.1

Command was expanded to include VLAN interfaces.

Functional Notes

The snmp trap link-status command is used to control the RFC 2863 ifLinkUpDownTrapEnable OID (OID
number 1.3.6.1.2.1.31.1.1.1.14.0).

Usage Examples

The following example disables the link-status trap on the VLAN interface:

(config)#interface vlan 1

(config-interface-vlan 1)#no snmp trap link-status

Advertising