Connect-mode [answer | originate | either – ADTRAN 1000R Series User Manual

Page 790

Advertising
background image

Command Reference Guide

Demand Interface Configuration Command Set

61200510L1-35E

Copyright © 2005 ADTRAN

790

connect-mode [answer | originate | either]

Use the connect-mode command to configure the interface to only answer calls, only originate calls, or to
both answer and originate calls. Use the no form of this command to restore the default values.

Syntax Description

answer

Specifies the interface may be used to answer calls but not originate calls.

originate

Specifies the interface may be used to originate calls but not answer calls.

either

Specifies the interface may be used to answer and originate calls.

Default Values

By default the connect mode is set to both answer and originate calls.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.

Command History

Release 11.1

Command was introduced.

Usage Examples

The following example configures demand interface 1 to only answer calls:

(config)#interface demand 1

(config-demand 1)#connect-mode answer