Command Reference Guide

Ethernet Interface Configuration Command Set

61200510L1-35E

Copyright © 2005 ADTRAN

634

power inline [auto | legacy | never]

Use the power inline command to detect attached Powered Devices (PDs) and deliver 48 VDC, compliant
with the IEEE 802.3af power-over-Ethernet standard, to the PD via existing CAT5 cabling. To disable
power detection and supply, use the power inline never command.

Syntax Description

auto

Enables power detection and supply to PDs.

legacy

Enables power detection and supply of legacy non-IEEE 802.3af compliant PDs.

never

Disables power detection and supply to PDs.

Default Values

By default, PWR switches discover and provide power to IEEE compliant PDs.

Applicable Platforms

This command applies to the NetVanta 1000 and 1000R Power over Ethernet Series units.

Command History

Release 9.1

Command was introduced.

Usage Examples

The following example configures the ethernet interface to detect and supply power to PDs:

(config)#interface ethernet 0/3

(config-eth 0/3)#power inline auto