port-auth timeout [quiet-period <seconds> | re-authperiod <seconds> |

tx-period <seconds>]

Use the port-auth timeout command to configure various port authentication timers.

Syntax Description

quiet-period <seconds>

Specifies the amount of time the system will wait before attempting another

authentication once a failure has occurred. Range is 1 to 65,535.

re-authperiod <seconds>

Specifies the amount of time between scheduled re-authentication attempts.

Range is 1 to 4,294,967,295.

tx-period <seconds>

Specifies the amount of time the authenticator will wait between identity

requests. Range is 1 to 65,535.

Default Values

By default, quiet-period is set to 60 seconds, re-authperiod is set to 3600 seconds (1 hour), and

tx-period is set to 30 seconds.

Applicable Platforms

This command applies to the NetVanta 1000 and 1000R Series units.

Command History

Release 10.1

Command was introduced.

Usage Examples

The following example sets the quiet-period to 10 seconds:

(config)#port-auth timeout quiet-period 10