Clock rate [auto | bps56k | bps64k – ADTRAN 1000R Series User Manual

Page 579

Advertising
background image

Command Reference Guide

DDS Interface Configuration Command Set

61200510L1-35E

Copyright © 2005 ADTRAN

579

clock rate [auto | bps56k | bps64k]

Use the clock rate command to configure the data rate used as the operating speed for the interface. This
rate should match the rate required by the DDS service provider. Use the no form of this command to
return to the default value.

Syntax Description

auto

Automatically detects the clock rate and sets to match.

bps56k

Sets the clock rate to 56 kbps.

bps64k

Sets the clock rate to 64 kbps.

Default Values

By default, the rate is set to auto.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, and 4000 Series units.

Command History

Release 1.1

Command was introduced.

Functional Notes

When operating at 64 kbps (clear channel operation), the DTE data sequences may mimic network loop
maintenance functions and erroneously cause other network elements to activate loopbacks. Use the
data-coding scrambled command to prevent such occurrences. See

data-coding scrambled

on page 581

for related information.

Usage Examples

The following example configures the clock rate for 56 kbps operation:

(config)#interface dds 1/1

(config-dds 1/1)#clock rate bps56k

Advertising