logging email priority-level [error | fatal | info | notice | warning]

Use the logging email priority-level command to set the threshold for events sent to the addresses
specified using the logging email address-list command. All events with the specified priority or higher
will be sent to all addresses in the list. The logging email on command must be enabled. Refer to logging
email address-list <email address> ; <email address>

on page 461

and logging email on

on page 463

for

related information. Use the no form of this command to return to the default priority.

Syntax Description

Sets the minimum priority threshold for sending messages to email addresses specified using the logging
email address-list
command.

The following priorities are available (ranking from lowest to highest):

error

Logs events with error and fatal priorities.

fatal

Logs only events with a fatal priority.

info

Logs all events.

notice

Logs events with notice, warning, error, and fatal priorities.

warning

Logs events with warning, error, and fatal priorities.

Default Values

By default, the logging email priority-level is set to warning.

Applicable Platforms

This command applies to the NetVanta 300, 1000, 1000R, 2000, 3000, 4000, and 5000 and
Total Access 900 Series units.

Command History

Release 1.1

Command was introduced.

Usage Examples

The following example sends all messages with warning level or greater to the email addresses listed
using the logging email address-list command:

(config)#logging email priority-level warning