framing [crc4]

Use the framing command to configure the framing format for the E1 interface. This parameter should
match the framing format provided by the service provider or external device. Use the no form of this
command to return to the default value.

Syntax Description

crc4

Enables CRC-4 bits to be transmitted in the outgoing data stream. Also, the
received signal is checked for CRC-4 errors.

Default Values

By default, CRC-4 is disabled.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.

Command History

Release 5.1

Command was introduced.

Functional Notes

The framing value must match the configuration of the E1 circuit. A mismatch will result in a loss of frame
alarm.

Usage Examples

The following example configures the E1 interface for CRC-4 framing:

(config)#interface e1 1/1

(config-e1 1/1)#framing crc4