thresholds [BES | CSS | DM | ES | LCV | LES | PCV | SEFS | SES | UAS]

[15Min | 24Hr] <threshold count>

Use the thresholds command to specify DS1 performance counter thresholds. Use the no form of this
command to return to default settings.

Syntax Description

BES

Specifies the bursty errored seconds threshold.

CSS

Specifies the controlled slip seconds threshold.

DM

Specifies the degraded minutes threshold.

ES

Specifies the errored seconds threshold.

LCV

Specifies the line code violations threshold.

LES

Specifies the line errored seconds threshold.

PCV

Specifies the path coding violations threshold.

SEFS

Specifies the severely errored framing seconds threshold.

SES

Specifies the severely errored seconds threshold.

UAS

Specifies the unavailable seconds threshold.

15Min

Specifies that the threshold you are setting is for the counter’s 15 minute statistics.

24Hr

Specifies that the threshold you are setting is for the counter’s 24 hour statistics.

<threshold>

Specifies the maximum occurrences allowed for this error type. Once a threshold
is exceeded, an event is sent to the console specifying the appropriate counter.
Additionally, if SNMP traps are enabled, the unit will send a trap with the same
information as the console event.

Default Values

The default values for this command are as follows:

thresholds BES 15Min 10

thresholds BES 24Hr 100

thresholds CSS 15Min 1

thresholds CSS 24Hr 4

thresholds DM 15Min 1

thresholds DM 24Hr 4

thresholds ES 15Min 65

thresholds ES 24Hr 648

thresholds LCV 15Min 13340

thresholds LCV 24Hr 133400

thresholds LES 15Min 65

thresholds LES 24Hr 648

thresholds PCV 15Min 72

thresholds PCV 24Hr 691

Threshold settings are applied to ALL DS1s.