Outage-retrain – ADTRAN 1000R Series User Manual

Page 695

Advertising
background image

Command Reference Guide

SHDSL Interface Configuration Command Set

61200510L1-35E

Copyright © 2005 ADTRAN

695

outage-retrain

Use the outage-retrain command to cause the SHDSL interface to force the SHDSL retrain sequence
(which takes the line down temporarily) if the interface detects more than ten consecutive errored seconds.
A retrain is forced in hopes that the newly retrained line will achieve better performance than the previous
training state. Use the no version of the command to disable this feature.

Syntax Description

No subcommands.

Default Values

By default, this feature is disabled.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, and 4000 Series units.

Command History

Release 3.1

Command was introduced.

Usage Examples

The following example forces a retrain sequence on the SHDSL interface:

(config)#interface shdsl 1/1

(config-shdsl 1/1)#outage-retrain

Advertising