ADTRAN 1000R Series User Manual

Page 200

Advertising
background image

Command Reference Guide

Enable Mode Command Set

61200510L1-35E

Copyright © 2005 ADTRAN

200

Functional Notes

The following is a list of output messages from the show interfaces shdsl command:

Equipment Type

Shows whether the unit is operating in CPE (NT) mode or CO (LT) mode.

Line Rate

Shows the current line rate. The line rate is the data rate + 8 kbps.
Therefore, a rate of 2056 kbps implies an actual data rate of 2048 kbps.

Alarms

Shows the current alarm conditions. Possible alarms are:

LOS

LOSW - Loss of synchronization word (related to frame sync)

Loop attenuation (loop attenuation margin threshold has been
reached or exceeded; this threshold is user selectable and disabled
by default)

SNR margin (SNR margin threshold has been reached or
exceeded; this threshold is also user programmable)

CRC

Segment defect

Segment anomaly

Loop Status

Shows additional information about the loop status as well as the
Embedded Operations Channel (EOC). Possible messages are:

SHDSL training complete (marginal signal quality). Establishing
EOC...

SHDSL training complete (marginal signal quality). EOC is up.

SHDSL training complete. EOC is down.

SHDSL training complete. EOC is up.

SHDSL training in progress.

Loopback State

Shows the state of local and remote loopbacks. Possible local loopback
messages are:

Local dual-sided loopback

Local customer transparent loopback

Local customer non-transparent loopback

Local transparent network loopback

Local non-transparent network loopback

No local loopbacks

Possible remote loopback messages are:

Remote dual-sided loopback

Remote customer transparent loopback

Remote customer non-transparent loopback

Remote transparent network loopback

Remote non-transparent network loopback

No remote loopbacks

SNR margin

Shows the current, minimum, and maximum signal-to-noise ratio of the
line. These may be cleared using the clear counters shdsl <slot/port>
command.