Frame-relay intf-type [dce | dte | nni – ADTRAN 1000R Series User Manual

Page 847

Advertising
background image

Command Reference Guide

Frame Relay Interface Config Command Set

61200510L1-35E

Copyright © 2005 ADTRAN

847

frame-relay intf-type [dce | dte | nni]

Use the frame-relay intf-type command to define the Frame Relay signaling role needed for the endpoint.
Use the no form of this command to return to the default value.

Syntax Description

dce

Specifies DCE or network-signaling role. Use this interface type when you need
the unit to emulate the frame switch.

dte

Specifies DTE or user-signaling role. Use this interface type when connecting to a
Frame Relay switch (or piece of equipment emulating a frame switch).

nni

Configures the interface to support both network and user signaling (DTE or DCE)
when necessary.

Default Values

By default, frame-relay intf-type is set to dte.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.

Command History

Release 1.1

Command was introduced.

Usage Examples

The following example configures the Frame Relay endpoint for DCE signaling:

(config)#interface frame-relay 1

(config-fr 1)#frame-relay intf-type dce

Advertising