Loopback remote line [fdl | inband – ADTRAN 1000R Series User Manual

Page 704

Advertising
background image

Command Reference Guide

T1 Interface Configuration Command Set

61200510L1-35E

Copyright © 2005 ADTRAN

704

loopback remote line [fdl | inband]

Use the loopback remote line command to send a loopback code to the remote unit to initiate a line
loopback. Use the no form of this command to send a loopdown code to the remote unit to deactivate the
loopback.

Syntax Description

fdl

Uses the facility data link (FDL) to initiate a full 1.544 Mbps physical (metallic)
loopback of the signal received by the remote unit from the network.

inband

Uses the inband channel to initiate a full 1.544 Mbps physical (metallic) loopback
of the signal received by the remote unit from the network.

Default Values

No defaults necessary for this command.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.

Command History

Release 1.1

Command was introduced.

Functional Notes

The following diagram depicts the difference between a line and payload loopback.

Usage Examples

The following example initiates a remote line loopback using the FDL:

(config)#interface t1 1/1

(config-t1 1/1)#loopback remote line fdl

T1 Network Interface

DS1

NI CSU

Payload Loopback

Line Loopback