Dial-backup maximum-retry <attempts – ADTRAN 1000R Series User Manual

Page 881

Advertising
background image

Command Reference Guide

Frame Relay Sub-Interface Config Command Set

61200510L1-35E

Copyright © 2005 ADTRAN

881

dial-backup maximum-retry <attempts>

Use the dial-backup maximum-retry command to select the number of calls the router will make when
attempting to backup a link. Use the no form of this command to return to the default state. For more
detailed information on Frame Relay dial-backup functionality, refer to the Functional Notes and
Technology Review sections of the command dial-backup call-mode [answer | answer-always | originate |
originate-answer | originate-answer-always]

on page 876

.

Syntax Description

<attempts>

Selects the number of call retries that will be made after a link failure (valid range:
0 to 15).

Setting this value to 0 will allow unlimited retries during the time the network is
failed.

Default Values

By default, dial-backup maximum-retry is set to 0 attempts.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.

Command History

Release 1.1

Command was introduced.

Usage Examples

The following example configures the AOS to retry a dial-backup call four times before considering backup
operation not available:

(config)#interface frame-relay 1.16

(config-fr 1.16)#dial-backup maximum-retry 4

Advertising