auto-cost reference-bandwidth <rate>

Use the auto-cost reference-bandwidth command to assign a different interface cost to an interface.

It

may be necessary to assign a higher number to high-bandwidth links

.

This value is used in OSPF metric

calculations.

Syntax Description

<rate>

Sets the default reference bandwidth rate (range: 1 to 4,294,967 Mbps).

Default Values

By default, the rate is set to 100.

Applicable Platforms

This command applies to the NetVanta 300, 1000R, 2000, 3000, 4000, and 5000 and Total Access 900
Series units.

Command History

Release 3.1

Command was introduced.

Usage Examples

The following example sets the auto cost reference-bandwidth to 1000 Mbps:

(config)#router ospf

(config-ospf)#auto-cost reference-bandwidth 1000