frame-relay lmi-t391dte <seconds>

Use the frame-relay lmi-t391dte command to set the T391 signal polling timer for the DTE endpoint.
Typical applications should leave the default value for this timer. Use the no form of this command to
return to the default value.

Syntax Description

<seconds>

Sets the timer value in seconds (valid range: 5 to 30).

Default Values

By default, the signal polling timer for the DTE endpoint is set to 10 seconds.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.

Command History

Release 1.1

Command was introduced.

Functional Notes

The T391 timer sets the time (in seconds) between polls to the Frame Relay network.

Usage Examples

The following example sets the T391 timer for 15 seconds:

(config)#interface frame-relay 1

(config-fr 1)#frame-relay lmi-t391dte 15