show system

The show system command shows the system version, timing source, power source, and alarm relay
status.

Syntax Description

No subcommands.

Default Values

No default value necessary for this command.

Applicable Platforms

This command applies to the NetVanta 300, 1000R, 2000, 3000, 4000, and 5000 and Total Access 900
Series units.

Command History

Release 6.1

Command was introduced.

Usage Examples

The following is sample output for this command:

>enable

#show system

ADTRAN, Inc. OS version 07.00.20
Checksum: 3B2FCC0F, built on Tue Jun 01 13:36:36 2004
Boot ROM version 07.00.20
Checksum: 604D, built on: Tue Jun 01 13:59:11 2004

Copyright (c) 1999-2004, ADTRAN, Inc.

Platform: Total Access 900

Serial number TechPub

Flash: 8388608 bytes DRAM: 33554431 bytes

ICP uptime is 0 days, 0 hours, 53 minutes, 50 seconds

System returned to ROM by External Hard Reset

Current system image file is "070020.biz"

Boot system image file is "070020.biz"

Power Source: AC

Primary System clock source config: t1 0/1

Secondary System clock source config: t1 0/1

Active System clock source: t1 0/1

Alarm Relay: OPEN