clock no-auto-correct-dst

The clock no-auto-correct-dst command allows you to override the automatic one-hour correction for
Daylight Saving Time (DST).

Syntax Description

No subcommands.

Default Values

No default value is necessary for this command.

Applicable Platforms

This command applies to the NetVanta 300, 1000, 1000R, 2000, 3000, 4000, and 5000 and
Total Access 900 Series units.

Command History

Release 6.1

Command was introduced.

Functional Notes

Many time zones include an automatic one-hour correction for daylight saving time at the appropriate time.
You may override it at your location using this command.

Usage Examples

The following example overrides the one-hour offset for DST:

>enable

#clock no-auto-correct-dst