Test-pattern [ones | zeros – ADTRAN 1000R Series User Manual

Page 669

Advertising
background image

Command Reference Guide

G.703 Interface Configuration Command set

61200510L1-35E

Copyright © 2005 ADTRAN

669

test-pattern [ones | zeros]

Use the test-pattern command to activate the built-in pattern generator and begin sending the specified
test pattern. This pattern generation can be used to verify a data path when used in conjunction with an
active loopback. Use the no form of this command to cease pattern generation.

Syntax Description

ones

Generates a test pattern of continous ones.

zeros

Generates a test pattern of continous zeros.

Default Values

No defaults necessary for this command.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.

Command History

Release 5.1

Command was introduced.

Release 6.1

Command was expanded to include E1 and G.703 interfaces.

Usage Examples

The following example activates the pattern generator for a stream of continuous ones:

(config)#interface e1 1/2

(config-e1 1/2)#test-pattern ones

Advertising