Frame-relay lmi-n392dte <threshold – ADTRAN 1000R Series User Manual

Page 851

Advertising
background image

Command Reference Guide

Frame Relay Interface Config Command Set

61200510L1-35E

Copyright © 2005 ADTRAN

851

frame-relay lmi-n392dte <threshold>

Use the frame-relay lmi-n392dte command to set the N392 error threshold for the DTE endpoint. Typical
applications should leave the default value for this setting. Use the no form of this command to return to
the default value.

Syntax Description

<threshold>

Sets the threshold value (valid range: 1 to 10).

Default Values

By default, the error threshold for the DTE endpoint is set to three errors.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.

Command History

Release 1.1

Command was introduced.

Functional Notes

If the error threshold is met, the signaling state status is changed to down, indicating a service-affecting
condition. This condition is cleared once N393 consecutive error-free events are received. N392 defines
the number of errors required in a given event window, while N393 defines the number of polling events in
each window.

For example:

If N392 = 3 and N393 = 4, then if three errors occur within any four events, the interface is determined
inactive.

Usage Examples

The following example sets the N392 threshold for five errors:

(config)#interface frame-relay 1

(config-fr 1)#frame-relay lmi-n392dte 5