Frame-relay lmi-t392dce <seconds – ADTRAN 1000R Series User Manual

Page 855

Advertising
background image

Command Reference Guide

Frame Relay Interface Config Command Set

61200510L1-35E

Copyright © 2005 ADTRAN

855

frame-relay lmi-t392dce <seconds>

Use the frame-relay lmi-t392dce command to set the T392 polling verification timer for the DCE
endpoint. Typical applications should leave the default value for this timer. Use the no form of this
command to return to the default value.

Syntax Description

<seconds>

Sets the timer value in seconds (valid range: 5 to 30).

Default Values

By default, the polling verification timer for the DCE endpoint is set to 10 seconds.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.

Command History

Release 1.1

Command was introduced.

Functional Notes

The T392 sets the timeout (in seconds) between polling intervals. This parameter needs to be a few
seconds longer than the T391 setting of the attached Frame Relay device.

Usage Examples

The following example sets the T392 timer for 15 seconds:

(config)#interface frame-relay 1

(config-fr 1)#frame-relay lmi-t392dce 15

Advertising