Storm-control action [shutdown – ADTRAN 1000R Series User Manual
Page 648
Command Reference Guide
Ethernet Interface Configuration Command Set
61200510L1-35E
Copyright © 2005 ADTRAN
648
storm-control action [shutdown]
Use the storm-control action command to select the action taken when a storm occurs. To disable the
option, use the no version of this command.
Syntax Description
shutdown
Shuts down the interface during a storm.
Default Values
By default, this command is disabled; the interface will only filter traffic.
Applicable Platforms
This command applies to the NetVanta 300, 1000, and 1000R Series units.
Command History
Release 5.1
Command was introduced.
Functional Notes
Enabling this option shuts down the interface if a multicast, unicast, or broadcast storm occurs.
Usage Examples
The following example shuts down Ethernet interface 0/1 if a storm is detected:
(config)#interface eth 0/1
(config-eth 0/1)#storm-control action shutdown