Inband-protocol [pn127 | v54 – ADTRAN 1000R Series User Manual

Page 690

Advertising
background image

Command Reference Guide

SHDSL Interface Configuration Command Set

61200510L1-35E

Copyright © 2005 ADTRAN

690

inband-protocol [pn127 | v54]

Use the inband-protocol command to designate the inband loopback pattern to send/detect on the SHDSL
interface. Use the no form of this command to return to default.

Syntax Description

pn127

Selects PN127 as the inband loopback pattern to send/detect.

v54

Selects V.54 as the inband loopback pattern to send/detect.

Default Values

By default, the inband-protocol is set to v54.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, and 4000 Series units.

Command History

Release 4.1

Command was introduced.

Functional Notes

Inband loopbacks are specific patterns that are sent in place of user data to trigger a loopback. Both
PN127 and V.54 are industry-standard loopback patterns used to allow remote loopbacks.

Usage Examples

The following example sets the inband loopback pattern for PN127:

(config)#interface shdsl 1/1

(config-shdsl 1/1)#inband-protocol pn127

Advertising