loopback remote line [inband]

Use the loopback remote line inband command to send a loopback code to the remote unit to initiate a
line loopback. Use the no form of this command to send a loopdown code to the remote unit to deactivate
the loopback.

Syntax Description

inband

Uses the inband channel to initiate a full 1.544 Mbps physical (metallic) loopback
of the signal received by the remote unit from the network.

Default Values

No defaults necessary for this command.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.

Command History

Release 1.1

Command was introduced.

Functional Notes

A remote loopback can only be issued if a cross-connect does not exist on the interface and if the signaling
mode is set to none. The following diagram depicts the difference between a line and payload loopback.

Usage Examples

The following example initiates a remote line loopback using the inband channel:

(config)#interface t1 1/2

(config-t1 1/2)#loopback remote line inband