611

test-pattern [clear | insert | ones| p215 | p220 | p511 | qrss | zeros]

Use the test-pattern command to activate the built-in pattern generator and begin sending the specified
test pattern. This pattern generation can be used to verify a data path when used in conjunction with an
active loopback. Use the no form of this command to cease pattern generation.

Syntax Description

clear

Clears the test pattern error count.

insert

Inserts an error into the currently active test pattern. Display the injected error
result using the show test-pattern command.

ones

Generates test pattern of continous ones.

p215

Generates a pseudorandom test pattern sequence based on a 15-bit shift register.

p220

Generates a pseudorandom test pattern sequence based on a 20-bit shift register.

p511

Generates a test pattern of repeating ones and zeros.

qrss

Generates a test pattern of random ones and zeros.

zeros

Generates test pattern of continous zeros.

Default Values

No defaults necessary for this command.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.

Command History

Release 5.1

Command was introduced.

Usage Examples

The following example activates the pattern generator for a stream of continuous ones:

(config)#interface e1 1/1

(config-e1 1/1)#test-pattern ones