frame-relay lmi-n393dte <counter>

Use the frame-relay lmi-n393dte command to set the N393 LMI monitored event counter for the DTE
endpoint. Typical applications should leave the default value for this counter. Use the no form of this
command to return to the default value.

Syntax Description

<counter>

Sets the counter value (valid range: 1 to 10).

Default Values

By default, the LMI monitored event counter for the DTE endpoint is set to four events.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.

Command History

Release 1.1

Command was introduced.

Usage Examples

The following example sets the N393 threshold for five events:

(config)#interface frame-relay 1

(config-fr 1)#frame-relay lmi-n393dte 5